CTC CombiAir 6M Air Source Heat Pump

£4,461.62 inc. VAT

[£3,718.02 exc. VAT]
For assistance call us on: 01260 228 822

In Stock! Order Now...

Description

CTC CombiAir 6M Key Features:

  • Compact Size: Perfect for smaller installations without compromising on performance.
  • Heating & Cooling: Provides year-round indoor comfort, even in extreme conditions (-20°C).
  • Energy Efficient: Rated A+++ for heating systems at 35°C, ensuring reduced running costs.
  • Quiet Operation Mode: Designed for noise-sensitive environments.
  • Smart Control: Remote monitoring and control with the myUplink app.
  • Eco-Friendly Refrigerant: R410A with low CO2 equivalent emissions.

Learn more about the CTC CombiAir 6M here.

Electrical Data CombiAir 6M CombiAir 8M CombiAir 12M CombiAir 16M
CTC no. 589350001 589351001 589352001 589353001
Weight (packaged weight) kg 67/87 91/111 109/131 144/166
Dimensions (depth x width x height) mm 364 x 993 x 791 422 x 1035 x 895 452 x 1145 x 995 452 x 1145 x 1450
Electrical data, connection 230V ~ 50Hz, 230V 2 ~ 50Hz
Energy efficiency class in heating systems @ 35/55˚C (A+++ to G) A+++/A++ A+++/A++ A+++/A++ A+++/A++
Energy efficiency class @ 35/55˚C (A+++ to D) A+++/A++ A+++/A++ A+++/A++ A+++/A++
Nominal heat output (Pdesignh) @ cold climate 35/55˚C kW 2021-05-04 00:00:00 2021-08-08 00:00:00 2021-12-12 00:00:00 15/15
Nominal heat output (Pdesignh) @ average climate 35/55˚C kW 2021-05-05 00:00:00 2021-07-08 00:00:00 2021-10-12 00:00:00 15/14
Nominal heat output (Pdesignh) @ hot climate 35/55˚C kW 2021-06-04 00:00:00 2021-10-09 00:00:00 2013-12-01 00:00:00 15/16
Rated current A 15 16 23 25
Ingress protection class (IP) IP 24 IP 24 IP 24 IP 24
Rated power, nominal: W35 & A + 7 / + 2 / -7 (EN14511) kW 2.67 / 2.32 / 4.64 3.86 / 5.11 / 6.6 5.21 / 6.91 / 9 7.03 / 9.33 / 12.1
COP: W35 & A + 7 / + 2 / -7 (EN14511) 5.32 / 4.20 / 2.57 4.65 / 3.76 / 2.68 4.78 / 3.86 / 2.75 4.85 / 3.92 / 2.80
Cooling capacity: A27 & W7 / 18 (EN14511) 5.87 / 7.98 7.52 / 11.20 9.87 / 11.70 13.30 / 17.70
EER: A27 & W7 / 18 (EN14511) 3.56 / 4.52 3.17 / 3.50 3.13 / 3.52 3.33 / 3.91
Nominal airflow m3/h 2530 3000 4380 6000
Refrigerant quantity (R410A, flourinated greenhouse gas GWP 2088) kg 1.5 2.55 2.9 4
CO2 equivalent tons 3.13 5.32 6.06 8.35
Sound power LWA @ 7/35 | 7/55 (EN14511) dB(A) 50 54 57 61
Sound pressure LPA 5 m @ 7/35 | 7/55 dB(A) 31 35 38 42
Sound pressure LPA 10 m @ 7/35 | 7/55 dB(A) 25 29 32 36