Description

LG, Life's Good
  • Black Fin Heat Exchanger
  • 100% heating capacity at -7°C (@LWT 55°C)
  • CO~P up to 4.90 (7°/35°)
  • Intuitive Interface – User friendly

 

Split – High Temperature

LG’s Therma V Split uses renewable technologies to heat water to 80°C but using less energy. Smart heating and hot water system for poorly insulated homes.
THERMA V Split High Temperature provides hot water up to 80˚C degrees. It is suitable for houses which have poor insulation or existing old radiator. It could also be used to meet sanitary water regulation which needs high water temperature. THERMA V Split High Temperature can be replaced with boiler system easily.
Heat generated by the outdoor unit via heat exchange with external air is transferred to the indoor unit to provide heating and hot water.
Water outflow temperature will follow outdoor temperature automatically with Weather Dependent Operation. If outdoor temperature decreases, heating capacity for the house will increase automatically in order to keep same room temperature.
Even in case of sudden product error, THERMA V continues ongoing heat production until proper service takes place. In case of minor error which is mainly caused by sensor malfunctioning, heat pump cycle is forced to operate. For major errors caused by defects in cycle parts, electric heater runs to maintain heating operation.
Excellent Performance
• Higher energy efficiency.
• Enhanced efficiency & Performance.
• Cascade 2 stage compression.
Time saving commissioning
• Efficient & Flexible design.
• Light weight.
User convenience
• Suitable for old radiator.
• Low noise.
• Quick defrosting
A split air-to-water heat pump system consists of two parts.
1) an outdoor heat pump and
2) an indoor floor standing unit connected via refrigerant pipe work.
The advantage is the two units can be far apart (up to 50m away and/or 30m height difference)  the outdoor unit can be positioned away from the home and the indoor unit connects to the wet central heating system as a traditional boiler. The indoor unit does not combust any fuel so there is no need for a chimney or flue and allowing the indoor unit to be situated anywhere inside the property.
This latest High Temperature Split from LG, provides excellent heating performance, especially at low ambient temperature. Even an outside temperatures of -7o C and LWT of 80o C, the HT  split is able to provide 16kW heating capacity (improved by 16.8% compared to the previous models).

16kW R32 High Temperature Split Indoor
HN1610H NK3

Features
R32 Split Hydro Box
R410A Split Hydro Box
High Temperature
Refrigerant & GWP R32 / 675 R410A / 2088 R410A / 2088
R134a / 1430
Capacity Range (kW) (1Ø) 5.5 / 7 / 9 (1Ø&3Ø) 12 / 14 / 16 (1Ø) 16
Energy Efficiency Class for Heating
A+++ / A++
for Heating
A+++ / A++
for Heating
A+ / A+
Energy Efficiency Class
Power Supply (V, Ø, Hz) 220-240, 1, 50 220-240, 1, 50
380-415, 3, 50
220-240, 1, 50
Dimension & Weight
ODU
950 × 834 × 330 / 60.0 950 x 1,380 x 330 / (1Ø) 84.8 (3Ø) 85.4 950 x 1,380 x 330 / 89.0
Dimension & Weight
IDU
490 × 850 × 315 / 38.1 490 x 850 x 315 / (1Ø) 40.5 (3Ø) 41.5 520 x 1,080 x 330 / 84.0
Sound Power Level
ODU (dB(A))
60 63 / 64 / 65 63
Sound Power Level
IDU (dB(A))
44 44 58 ~ 63
Operation Range (OAT, ℃) Heating : -25 ~ 35
Cooling : 5 ~ 48
Heating : -25 ~ 35
Cooling : 5 ~ 48
Heating : -25 ~ 35
Operation Range (LWT, ℃) Heating : 15 ~ 65
Cooling : 5 ~ 27 (16 ~ 27)2)
Heating : 15 ~ 57
Cooling : 5 ~ 27 (16 ~ 27)2)
Heating : 25 ~ 80
Operation Range (LWT, ℃) DHW : 15 ~ 803) DHW : 15 ~ 803) DHW : 25 ~ 80
Model Name
(ODU, 1Ø)
HU051MR U44
HU071MR U44
HU091MR U44
HU121MA U33
HU141MA U33
HU161MA U33
HU161HA U33
Model Name
(ODU, 3Ø)
HU123MA U33
HU143MA U33
HU163MA U33
Model Name
(IDU)
HN091MR NK5 HN1616M NK5
HN1636M NK5
HN1610H NK3

1) 5.5 & 7kW : profile L / 9 kW : profile XL
2) When fan coil unit is not used.
3) DHW 58 ~ 80°C operating is available only when the electric heater is operating.
*ODU : Outdoor Unit, IDU : Indoor Unit
**OAT : Outdoor Air Temperature, LWT : Leaving Water Temperature

Delivery

Please contact us for precise delivery times.

Support

Call Our Team:

01260 228 822

Mon - Fri: 9am - 6pm

Standard warranty for LG products is 3 years.

If the installer has completed the 1 day LG Technical Training course, an extended 7 year warranty can be applied.

If you are interested in becoming an accredited installer, one-day courses are run by Unitherm in Exeter, and can be booked here:  https://www.unitherm.co.uk/pages/training. Courses cost £95 + VAT for the 1 day.  If the installer then goes on to purchase an LG unit, then LG/Unitherm will refund the cost of the course.

For installers that are new to fitting heat pumps, (e.g. gas installers that are looking to branch out), Unitherm also run a 3 day Installation & Maintenance of Air Source Heat Pumps Course which provides the knowledge and tools required to install competently. Book here: https://www.unitherm.co.uk/pages/training.