Panasonic Aquarea 9kW J Generation R32 Monobloc Heat Pump
- Description
- MANUALS
- DELIVERY
- WARRANTY
Description
Contact us on: 01260 228 822
email us at info@theheatpumpwarehouse.co.uk

The Panasonic Aquarea 9kW J-Generation Monobloc is engineered to deliver high-capacity heating, cooling and domestic hot water through a single outdoor unit.
The monobloc architecture keeps all refrigeration components outside — meaning no refrigerant pipework, no F-Gas handling, and quicker installation. Simply connect water in/out, power, and controls.
Designed for UK weather, it maintains strong heating performance down to –20°C and keeps full rated capacity down to –7°C, making it ideal for retrofit and new-build applications.
(Controller included)
Key Features
-
9.0 kW heating output @ A7/W35 with a COP of 4.60
-
Uses low-GWP R32 refrigerant
-
A+++ ErP rating at 35°C (A++ at 55°C)
-
Delivers flow temperatures up to 60°C – suitable for radiators or underfloor heating
-
Guaranteed operation from –20°C to +35°C
-
Quiet performance with 60 dB(A) sound power at part load
-
Monobloc design – no refrigerant connections
-
Integrated 3 kW backup heater
-
Built-in variable-speed circulation pump
-
Optional Aquarea Smart Cloud remote access
-
Supports hybrid operation with a gas/oil boiler
Installer Benefits
-
No need for F-Gas certification (factory-sealed refrigerant circuit)
-
Extremely fast installation — pre-integrated pump, heater, sensors, protection devices
-
Compact footprint: 865 × 1283 × 320 mm, approx. 110 kg
-
Flexible plumbing connections (R 1¼”)
-
Ideal for heat-loss requirements between 8–10 kW
-
Works seamlessly with Aquarea DHW cylinders, buffer tanks and controllers
Performance Data (from Panasonic spec)
Heating Capacity @ A7/W35: 9.00 kW
COP @ A7/W35: 4.60
Heating Capacity @ A7/W55: 9.00 kW
COP @ A7/W55: 2.68
SCOP (Average climate): 4.84 (35°C) / 3.26 (55°C)
Energy Class: A+++ (35°C) / A++ (55°C)
Heating operating range: –20°C to +35°C
Water outlet: 20–60°C
Cooling capability: 9.0 kW
Sound power:
-
Part load heating: 60 dB(A)
-
Full load heating: 69 dB(A)
Applications
-
Larger 3–5 bedroom homes
-
Properties with underfloor heating or low-temp rads
-
Boiler replacements (oil / LPG / gas)
-
Hybrid and bivalent systems
-
High-demand homes needing reliable output in winter
Please contact us for precise delivery times.
Call Our Team:
Mon - Fri: 9am - 5pm